DYNAMIC
- Very quiet operation 30.4 dB at 3 m
- Active cooling function
- Seasonal energy efficiency 199 %
- High COP 5.06 heating factor
- Intelligent cooperation with PV
- Very quiet operation 30.4 dB at 3 m
- Active cooling function
- Seasonal energy efficiency 199 %
- High COP 5.06 heating factor
- Intelligent cooperation with PV
PUMP FEATURES
The DYNAMIC heat pump with fluid power modulation ideally adapts to the needs of the building and thereby optimizes heating and hot water costs to the greatest possible extent. It achieves its high efficiency not only by controlling compressor power, but also by adjusting the speed of the fan and circulating pump. It achieves very quiet operation using specially designed blades, an ultra-quiet EC fan, and a perfectly acoustically insulated compressor.
Setting heat pump and heating system parameters is easy and intuitive using the touchscreen. Operating states and values, such as coefficient of performance, are clearly shown on a seven-inch color display. An electrical control panel is included to provide power switching for the backup heat source, circulation pumps, and individual control elements. Additional control and parameter settings are available for computer, laptop, tablet, smartphone, etc. ‒ every user can monitor and control the heat pump remotely.
DYNAMIC heat pumps are available in two models with a heating capacity range of 4-13 kW and 8-22 kW. These heat pumps already meet the requirements of the A+++ energy class. The DYNAMIC model is also available with active cooling.
DYNAMIC heat pumps meet strict Ecodesign requirements and are eligible for subsidies.
DOWNLOAD
TECHNICAL PARAMETERS
Type designation | HP3AWX 08 D | HP3AWX 08 DR | HP3AWX 16 D | HP3AWX 16 DR |
SVT code | SVT 21435 | SVT 23103 | SVT 21436 | SVT 23104 |
Energy class (35 °C) | ||||
Energy efficiency heating Ƞs (35 °C) | 193 % | 193 % | 197 % | 197 % |
SCOP (35 °C) | 4,89 | 4,89 | 4,99 | 4,99 |
Energy parameters (kW) | ||||
Heating capacity (A7/W35)(kW) | 5,3 — 10,0 | 5,3 — 10,0 | 10,2 — 16,0 | 10,2 — 16,0 |
Coefficient of Performance - COP (A7/W35) | 5,04 | 5,04 | 5,05 | 5,05 |
Cooling capacity (A35/W18) (kW) | — | 6,5 — 11,5 | — | 6,5 — 16,5 |
Other parameters | ||||
Noise level at 3 m (dB(A)) (standard / lowered fan rotation speed)* | 30,4 / 27,3 | 30,4 / 27,3 | 35,2 / 33,6 | 35,2 / 33,6 |
Compressor / Control / Refrigerant | MITSUBISHI Scroll / INVERTOR / R410A | |||
Dimensions mm) | w 1430 d 680 h 1140 | w 1430 d 680 h 1140 | w 1430 d 680 h 1360 | w 1430 d 680 h 1360 |
Weight (kg) | 215 | 220 | 250 | 255 |
Order number | W20307 | W20385 | W20308 | W20386 |
* Acoustic pressure level for halfspace without reflectional planes – see assembly instructions.
Easy assembly
The future in heating for its indisputable advantages of easy installation and universal use.
Heating capacity
Air-water heat pumps are characterised primarily by their high heating capacity and heating factor.
Quiet operation
Reliable operation even at extreme outdoor temperatures and very low noise levels.
References